maintaining the balance between load, generation, and external transfers; controlling the frequency and time error; implementing the interchange transactions. hbbd```b```RD L$m r7Hb\@@?|# h49@x5@ uK5
In the United States, the power system consists of more than 7,300 power plants, nearly 160,000 miles of high-voltage power lines, and millions of low-voltage power lines and distribution transformers, which connect 145 million customers. Generation resource mix, in megawatt-hours and percent. The COTP is jointly owned by several parties, including WAPA and BANC Members, via the Transmission Agency of Northern California. This page is not available in other languages. [ 1] The principal difference between the currently-effective regional . The Council develops a plan, updated every five years, to ensure the region's power supply and acquire cost-effective energy efficiency. As a Regional Transmission Organization, MISO manages the generation and transmission of electricity across high-voltage lines and assures consumers of unbiased regional grid management. These interconnections describe the physical system of the grid. 4. BANC - Balancing Authority of Northern California BCHA - British Columbia Hydro Authority BPAT - Bonneville Power Administration-Transmission CFE - Comision Federal de Electricidad CHPD - PUD No. Net imports-exports by state are provided for years 2004, 2005, and 2007. The entity that is the highest level of authority who is responsible for the Reliable Operation of the Bulk Electric System, has the Wide Area view of the Bulk Electric System, and has the operating tools, processes and procedures, including the authority to prevent or mitigate emergency operating situations in both next-day analysis and real-time operations.Read more The Greenhouse Gas Reporting Program (GHGRP) requires reporting of greenhouse gas (GHG) data and other relevant information from large GHG emission sources, fuel and industrial gas suppliers, and CO2 injection sites in the United States. Typically, EIA will make corrections to previously issued EIA-923 data. Hub Map - WECC Power & Gas. AVERT produces outputs including maps, charts, and tables, that display the location of emission reductions at the regional, state, and county level, on a monthly and annual basis. Bulk Electric System or BES. It also provides net generation at the prime mover level for all plants. The WECC is located in the west of Berlin, close to Tegel Airport, to Messe Berlin and the government quarter. The subregions were defined by EPA as a compromise between NERC regions (which EPA felt were too big) and balancing authorities (which EPA felt were generally too small). Similarly, WECCs mission today is to: Northwest Power Pool Area (NWPP) An RC oversees grid compliance with federal and regional grid standards, and can determine measures to prevent or mitigate system emergencies in day-ahead or real-time operations. The CH4emissions factors which eGRID uses changed in eGRID2014. The Eastern Interconnection consists of 36 balancing authorities: 31 in the United States and 5 in Canada. A balancing authority is responsible for operating a transmission control area. eGRID2021 is updated with 2021 data and includes the following change to the methodology: Please see the Technical Guide for more details. These operators monitor the grid to identify potential problems before a situation becomes critical. The three networks are: NERCs eight regional entities cover the 48 contiguous States and portions of Canada and Mexico. Lesson plans, science fair experiments, field trips, teacher guide, and career corner. U.S. Greenhouse Gas Inventory Reports include inventories of U.S. greenhouse gas emissions and sinks. International energy information, including overviews, rankings, data, and analyses. The addition of Puerto Rico resulted in the addition of a new State (Puerto Rico; PR), Balancing Authority (Puerto Rico Miscellaneous; NA), eGRID subregion (Puerto Rico Miscellaneous; PRMS), and NERC region (Puerto Rico; PR) to the eGRID2019 files. Energy Overview The Northwest Power Plan The 2021 Northwest Power Plan 2021 Plan Supporting Materials Planning Process and Past Power Plans Technical Tools and Models Regional Portfolio Model Applicability 4.1. that were reported in the Plant file in past editions of eGRID are included as a separate file (discontinued with the release of eGRID2019). The Electric Reliability Council of Texas (ERCOT) covers most, but not all, of Texas and consists of a single balancing authority. The Electric Reliability Council of Texas (ERCOT) covers most, but not all, of Texas and consists of a single balancing authority. Die technische Speicherung oder der Zugriff ist erforderlich, um Nutzerprofile zu erstellen, um Werbung zu versenden oder um den Nutzer auf einer Website oder ber mehrere Websites hinweg zu hnlichen Marketingzwecken zu verfolgen. If you choose to Reject all, we will not use cookies for these additional purposes. Is there additional eGRID data available? The Balancing Authority of Northern California (BANC) is a Joint Powers Authority (JPA) consisting of the Sacramento Municipal Utility District (SMUD), Modesto Irrigation District (MID), Roseville Electric, Redding Electric Utility (REU), Trinity Public Utility District (TPUD) and the City of Shasta Lake as its founding Members. It matches generation with load and maintains consistent electric frequency of the grid, even during extreme weather conditions or natural disasters. Tools to customize searches, view specific data sets, study detailed documentation, and access time-series data. 2013. The changes in the resource mix are often attributed to changes in the number of plants in an eGRID subregion (retirements or additions) or changes to operations at individual plants. The Emissions & Generation Resource Integrated Database (eGRID) is a comprehensive inventory of environmental attributes of electric power systems. States and local governments rely on eGRID data for electricity labeling (environmental disclosure programs), emission inventories, and registries as well as for efforts to analyze air emissions from the electric power sector. This is particularly true for the emission rates by fuel type, such as the emission rates for oil. Balancing Authority shall take or be taking the same or substantially similar actions when directing BWP to adjust their generation. Find local businesses, view maps and get driving directions in Google Maps. Maps, tools, and resources related to energy disruptions and infrastructure. Available from EPAs eGRID web site:https://www.epa.gov/egrid. The method for estimating CH4emissions from electricity generation involves multiplying the heat input (mmBtu) by a fuel-specific emissions factor. There are a few cases where the emissions rates decreased. The Balancing Authority is the responsible entity unless the Balancing Authority is a member of a Reserve Sharing Group, in which case, the Reserve Sharing Group . Hydro Quebec TransEnergie. BANC - Balancing Authority of Northern California BCHA - British Columbia Hydro Authority BPAT- Bonneville Power Administration - Transmission . This change returns the methodology to the approach used in eGRID2012 and previous editions. Assets for Public Service Company of Colorado - PSCO Learn More about Ansergy Request a Free Trial Request a Sample Forecast Methodology Asset ID - Asset Name Generation (MWH) Power Price ($/mwh) Nat Gas Price ($/mmbtu) Heat Rate (btu/kwh)/ Revenues ($) Gas Burn (mmbtu) Gas Cost ($) Gross Margin ($) 444 - Blue Spruce Energy [] The WIT is the primary means to confirm net scheduled interchange (NSI) for preschedule checkout based on the WECC Preschedule Calendar, next-hour checkout (from current operating hour), current-hour checkout upon change, past-hour checkout in current day . Please enable scripts and reload this page. In the EIA database, the WECC is split into three sub-regions, unlike the four that our model uses. endstream
endobj
8 0 obj
<>/OCGs[23 0 R 24 0 R 25 0 R 26 0 R 27 0 R 28 0 R 29 0 R 30 0 R 31 0 R 32 0 R 33 0 R]>>/PageMode/UseNone/Pages 5 0 R/Type/Catalog/ViewerPreferences 22 0 R>>
endobj
9 0 obj
<. Heat input and emissions values used to adjust combined heat and power (CHP) plants and biomass plants are added to the plant-level. Introduction . Red zone less than 15% reserve margin U.S. ETC F IS CALCULATED AS FOLLOWS: ETC F = NL F + NITS F + GF F . Several states have used eGRID to publish state specific emission information or have used eGRID to inform policy decisions. The Reserve Sharing Group when comprised of a Source Balancing Authority becomes the . Balancing Authority or Path Operator Flowgate or Qualifying Path Highest Level Duration Folsom, CA Calgary, AB . Assets for Avangrid - AVRN Learn More about Ansergy Request a Free Trial Request a Sample Forecast Methodology Asset ID - Asset Name Generation (MWH) Power Price ($/mwh) Nat Gas Price ($/mmbtu) Heat Rate (btu/kwh)/ Revenues ($) Gas Burn (mmbtu) Gas Cost ($) Gross Margin ($) 438 - Big Horn Wind II 1209 43.32 5.30 [] It is also useful to individuals seeking environmental information about the electric power sector in the United States. The California ISO has finalized agreements with 42 of the balancing authorities and transmission operators in the Western Interconnection to receive reliability coordinator services from ISO's RC West: . A flag identifying plants that contain CAMD-level data has been added to the plant-level spreadsheet. Wheelmap.org is an online map to search and find wheelchair-accessible places. For a fuel type such as coal or natural gas, which is the primary fuel type for many plants in each region, negative net generation does not have much impact on the overall emission rate. Come test out some of the products still in development and let us know what you think! Load and resource data submitted by the BA to WECC is used to identify areas that have the potential for electricity supply shortages. Electric Reliability Council of Texas, Inc. FRCC. 2. The generation data in eGRID are from the Energy Information Administration (EIA), which defines net generation as the total gross generation minus station use (which is the amount of electricity used to operate and maintain the electric power plant). If you choose to Accept all, we will also use cookies and data to. : For more information click the links inside the Popups, which appear if you hover above a pin within the map. Added a hyperlinked table of contents and color coding to the data file. What are the regional emission rates and resource mix? 1. A. The scenarios are divided into Classes to determine existing generation, fluctuations in generation and demand, the status and effect of planned generation additions, and the status and effect of planned transmission projects. Balancing Authority 4.1.1 A Balancing Authority receiving Overlap Regulation Service is not subject to Control Performance Standard 1 (CPS1) or Balancing Authority ACE Limit (BAAL) compliance evaluation 4.1.2 A Balancing Authority that is a member of a Regulation Reserve Sharing Group is the Responsible . EPA estimates that the GGL is about 5% of the electricity that is transmitted and distributed annually in the United States. A map of the interconnections is available here. G 30j3t/?5\33XR ^
Most, but not all, balancing authorities are electric utilities that have taken on the balancing responsibilities for a specific portion of the power system. Year-to-year differences in the regional CH4emission rates are explained by changes in each regions resource mix. The balancing authority data administrators are RC West and Southwest Power Pool (SPP). ,of Power Profiler is available. 2023. WECC - Wheelmap: Auf unserer Karte erkennen Sie, wie rollstuhlgerecht die Umgebung ist und wo Sie Schwierigkeiten bekommen knnten. Reports requested by congress or otherwise deemed important. For example, the California Air Resources Board, Climate Registry, Climate Action Reserve, and Greenhouse Gas Protocolcite eGRID for use in estimating scope-2 GHG emissions from electricity purchases in the United States. Credible Source of Interconnection-Wide Information- WECC provides training, education and information on key functions related to mandatory standards and compliance, as well as data, analysis and studies relating to transmission system planning, and renewable integration. Most of the eGRID emission data are from the Clean Air Markets Programs of EPA. The net generation in the Generator fileis based on unit-level generation data whereavailable. Balancing Authority or BA. Uranium fuel, nuclear reactors, generation, spent fuel. Western Interconnection-Wide Planning Facilitator- WECC provides planning functions (transmission planning and integration of resources) and policy-related functions as requested by members. ISO New England Inc. What other EPA tools are available to estimate avoided emissions from EE/RE programs? If you are interested in receiving email alerts when eGRID is updated or eGRID related news is released, sign up ateGRID Notification form. This plant was assigned the CAMX subregion based on its balancing authority, which is the Los Angeles Department of Water and Power. Most carbon footprint calculators that are applicable to the United States use eGRID data. The technical storage or access that is used exclusively for anonymous statistical purposes. Added unadjusted heat input for renewable fuels (which is calculated by EIA) to the Plant file. In some cases, the amount of station use electricity exceeds the total amount of electricity generated at the plant, and the total net generation is a negative number. eGRID data are cited by many emission inventory and registry protocols, various emission calculation tools and applications, hundreds of academic papers, and consultants; it is used for many research applications and efforts. Crude oil, gasoline, heating oil, diesel, propane, and other liquids including biofuels and natural gas liquids. Non-BA entities may designate reporting contacts in their organizations. The eGRID historicalZIP filecurrently contains the data and supplementary files (e.g., technical support documents, maps, summary tables, and release notes) for years 1996, 1997, 1998, 1999, 2000, 2004, 2005, 2007, 2009, 2010, 2012, 2014, and 2016. This is the same methodology used in all editions of eGRID. ERCOT is unique in that the balancing authority, interconnection, and the regional transmission organization are all the same entity and physical system. Another example is The University of California, BerkeleysCoolClimate Carbon Footprint Maps. RC West. For a relatively small number of plants (less than 0.1%), the sum of the generation by fuel type does not equal the total net generation at the plant. Nearly 400 million North American citizens depend on electricity in their daily lives. Die technische Speicherung oder der Zugriff, der ausschlielich zu statistischen Zwecken erfolgt. 13353 BerlinTel: +49 (0)30 89 06 42 55 E-Mail: anfrage@wecc.de, Westhafen Event & Convention CenterCookie-SettingsImprintPrivacy policyAVB. Replaced Boiler file with new Unit file; included the entire universe of units; not just the subset of boilers with unit-level data from EPA/CAMD or EIA. EPA aggregates the data and presents it for Alaska, Hawaii, and the Eastern, Western, and ERCOT NERC interconnections. The One example isCarbon Footprint Visualizationsby Carbon Visuals, which illustrates accurate volumetric images to visualize the carbon footprint of all U.S. power stations. 1752 [10]), and has said that together with . Greenhouse gas data, voluntary reporting, electric power plant emissions. Identified data sources at a more granular level. 2. Nader Samaan. The ISO's Western Energy Imbalance Market (WEIM) is a real-time energy market, the first of its kind in the western United States. Non-personalized ads are influenced by the content youre currently viewing and your general location. The output emission rates (e.g. A Consolidated Balancing Authority (CBA) is necessary for an Operating Reserves market to work. Wenn du deine Zustimmung nicht erteilst oder zurckziehst, knnen bestimmte Merkmale und Funktionen beeintrchtigt werden. These include: 4 Traded Hubs (PV, SP, NP, MidC) 30 Load Serving Balancing Authoritites. If a Balancing Authority does not have the necessary reserves, they will need to import from a neighboring Balancing Authority or increase the resources available to meet the demand. Lgcensed under CC BY-SA 3.0 via Wikimedia Commons - . For example, 2020 inventory year should use eGRID2020 and the 2021 inventory should use eGRID2021. A balancing authority is responsible for operating a transmission control area. the Eastern Interconnected System (from the Atlantic ocean to the Rocky Mountain States), the Western Interconnected System (for States west of the Rocky Mountains), and. The map also shows the location of substations, transmission lines and transmission zones. The Western Electricity Coordinating Council (WECC) recently published a report on the resource adequacy for the Western interconnection. Mass emissions are reported in either pounds or tons. eGRID2014 and subsequent eGRID editions use only EIA data, as well as a new formula (as described above). As defined in the NERC Rules of Procedure. 0
BANC provides its Members an ownership voice in all Balancing Authority decisions consistent with the principle of maximizing consumer value. The table below presents the revised CH4emissions rates (lbs. Monthly and yearly energy forecasts, analysis of energy topics, financial analysis, congressional reports. Regional Reliability Standard BAL-002-WECC-3 applies to balancing authorities and reserve sharing groups in the Western Interconnection, and it specifies the quantity and types of contingency reserves required to ensure reliability under normal and abnormal conditions. How can I receive eGRID related news from EPA? EIA's free and open data available as API, Excel add-in, bulk files, and widgets. BAL-002-WECC-3Contingency Reserve Page 1 of 13 . For example, the CO2 output emission rate for oil in the RMPA subregion is significantly higher than the oil rates for most other regions. . For example, users can select among wind, solar, and different EE savings options (load impact profiles) within the tool. 44 0 obj
<>stream
. Local electricity grids are interconnected to form larger networks for reliability and commercial purposes. A balancing authority (BA) is an entity in the US electric system (as well as in parts of Canada and Mexico) that is responsible for grid balancing: resource planning and unit commitment ahead of time, maintenance of the load-interchange-generation balance within a balancing authority area (also known as a control area) and support for real-time load-frequency control. The supporting documentation name was changed from Technical Support Document (TSD) to Technical Guide.