Refrigerator Norcold 121X Series Service Manual. The fridge had a couple fuses blown and the owners didnt know why the fridge wasnt working. If its plugged, it wont get hot enough to cool down normally. However, a malfunction can occur with any equipment. I went back to the books, and finally found the answer I had been looking for the entire time. Where are your replies? Its been on hour or so (electric mode) not getting cold. Have you tried using it on propane? For. Turn the thermostat control to the desired setting. If it's on or blinks, that means the pilot light isn't staying lit. Defrost freezer/remove and dry ice maker connection and module. The Norcold 121X RV refrigerator reset is a simple process that can be completed in just a few minutes. Refrigerator defaulted to propane gas operation, but did not establish a flame (gas lockout). If you own a Norcold RV refrigerator, then you know that its one of the best on the market. Dinner:We are open for dinner Thursday - Saturday, 5:00 PM - 9:00 PM Avoid placing your refrigerator in an area where it could be accidentally splashed or sprayed with water that could enter the electrical compartment of the refrigerator. The current is wrong (or fan current is wrong). If the door seal on your RV fridge is damaged or dirty, it can allow warm air to enter the fridge and prevent proper cooling. The orifice has a tiny rectangular hole the propane passes through and into the burner tube to create the perfect size and strength of the flame. However, if you follow these simple troubleshooting tips, you should be able to fix most issues yourself and keep your Norcold 121X running like new for years to come! Its worked like a charm both times and its so easy to do you may as well give it a shot before taking it to get fixed or replaced. Try This One Simple Trick, What To Do If Your RV Fridge Wont Get Cold. Save my name, email, and website in this browser for the next time I comment. The Norcold refrigerator's cooling unit is a series of tubing that draws out and absorbs heat using the phase change of hydrogen, ammonia, sodium chromate, and water. There is a simple solution for Dometic refrigerator troubleshooting check light issues. This is a fault within the refrigerator controls. Norcolds 121X series of RV refrigerators are some of the most popular on the market, and for good reason. Im glad it worked for you too. 1. - That the vehicle generator is operational (if applicable). Canadian customers and visitors: provinces and postal codes can also be searched here. I am 46. Turn the thermostat control to OFF. I had looked at the flame many times to make sure it was blue (it was) and even taken apart the burner to see if it was dirty but Id somehow missed what I was actually supposed to do. When you remove the bolt to the wind cover you will be able to move it back but you may not be able to remove it completely. Do not use a converter or battery charger to supply the DC power directly to the unit because these two devices do not supply filtered DC power. If lots of soot comes out the burner tube may have also been part of the problem. Refer to the operators guide provided with your refrigerator for more details: Close the door on a piece of paper that is about the size of a dollar bill and gently pull the paper. When they do that, there is a possibility of a fire. - That there is no air in the propane gas supply line. Ensure your RV batteries are charged with your multimeter voltage reader. Power light is on. It sounds like something I would try. You need at least one to work.4. Blank display- Refrigerator does not turn ON. It can be bypassed temporarily. Same goes with our water heater. If the power is working, open up the fridge door and locate the control panel inside. Red, flashes on five (5) times every five (5) seconds. Norcold sells its modules in kits containing a module and a sensor. Sometimes its even one piece. If the unit does not start to cool after two hours, contact your dealer or a Norcold authorized service center. The 1210 AC series cools only on AC power. My suggestion to RVers who are experiencing problems with their RV fridge not cooling properly is to always do this first. The second time we were camping up in the mountains and unable to get any rubbing alcohol so I improvised and used vodka. The thermister sensed inoperable, so temperature is being controlled by backup operating system. Re-connect dc power. You want to remove the lower door as this is the one that leads to all the propane parts including the burner and orifice. Does the RV fridge cool faster on propane? Simply close the refrigerator door correctly to clear the code. See Door Sealing.. These refrigerators electronic controls operate on 12 volt DC. Refrigerator Norcold 121X series Owner's Manual Rv refrigerators (40 pages) Refrigerator Norcold 1200XX Owner's Manual 12.0 cu.ft., 2-way, 4-door, r.v. First, if you have a Norcold refrigerator, good for you. (40F for the fridge and around 0 for the freezer). Make sure that your RV is parked on level ground before checking any other potential issues.2. I spent hours researching what could possibly be wrong with it online. Sadly, it still wasnt quite right. Does an RV refrigerator work better on gas or electricity? Gas/electric (35 pages) Refrigerator Norcold 1200ACXX Owner's Manual. See Also: Best Portable Quiet Inverter Generators For RV Camping. If the air vents are blocked by dirt or debris, this can prevent proper airflow and result in a warm fridge. Models start as low as $899, making them a great option for budget-minded RVers. The refrigerator is operating on the 'Back Up Operating System. Make sure the manual shut-off valve on the refrigerator is open when you see this error message. Make sure there are at least 3 inches of clearance on all three sides of the compressor compartment and at least 48 square inches of ventilation area above the compressor compartment. We take our motorhome to a local shop for its propane certification annually and they service the onboard tank and attachments, and connections to the appliances. Additionally, ensure that the gas supply line is free of air. Also, if youre not careful with your tools, you might damage delicate electronics or loosen a fastener. Why would I smell propane, no leak at orifice. This is not owner serviceable. Make sure that the refrigerator is correctly installed and that the vents are not blocked. I do not hear the fans running while in the AC or AU mode. The heating element is in the chimney so it makes sense that its getting hot but the fridge should also be getting cold. But some, like the refrigerator, have delicate electronics. There happens to be another 5amp fuse on the control board at the rear access panel. No matter what issue youre having with your fridge, this manual will help you get to the bottom of it and get your appliance back up and running again in no time.So, if youre looking for some assistance with your Norcold RV refrigerator, be sure to check out the official manual. My norcold 121X rv refrigerator will not turn on and we are puged into shore power . The flame is usually on the right-hand side under the flume which is the large cylinder that goes up behind the fridge. In other words, an incompatibility issue. Then, inspect the refrigerators power cord for any harm. If you go to the link I gave that leads to Amazon you will see in the product pictures where the heating element is located. Its true that you want as little space as possible between the back of the RV fridge and the wall. Hi, I am Peter Poole. Make sure the doors are fully closed and if you throw a whole bunch of warm stuff in there expect temps to rise until all that heat can be removed. The easy answer is no, but the reality is more complicated than that. If it lights, it is only how much gas goes through, and therefore how much heat that regulates the temp inside the refrigerator. - See your dealer or authorized Norcold Service Center. The first time I cleaned the RV fridge orifice I was able to use isopropyl alcohol and it worked great. Make sure the power switch/thermostat is not in the OFF position. Make sure theres nothing blocking vents or air intakes. Poor cooling on AUTO AC or AC manual mode. refrigerator; 12.0 cu.ft., 2-way, 4-door, r.v. If this happens, there are a few things you can check. Connect the refrigerator directly to the battery. It Doesnt Hurt to Try the Famous Reset Routine. Step 1: Go to the back of the RV and remove the refrigerator back access panel. I was born in Portland and I still live and work in this city, The importance and necessity of reset the control panel in the Samsung refrigerator, How to get rid of the problem when leaking water inside the fridge. sometimes removing the unit and laying it face down for an hour or so will allow the pooled up ammonia to flow out of the condenser , caused by lack of use .re-install an fire up. AC voltage is unavailable to the refrigerator control. Be aware of any cooling changes that are not because of weather, loading, or thermostat changes. 4 sounds like a little overkill but if you have an extra large RV fridge it might be necessary. refrigerator with ice maker (21 pages), Manual will be automatically added to "My Manuals", Location of Refrigerator Information Label, Location of Cooling System Serial Number Label Location, Blank Display- Refrigerator Does Not Turn on, Measuring DC Voltage Across P1-1/P1-6 with Wire Harness Disconnected, Measuring DC Voltage Across Yellow/Green and Green Wires - All Models, Optical Control Display AssemblyBack View, To Check White/Red Wire and Blue Wire for Continuity, Measuring DC Voltage Across the White/Red and White/Violet Wire, Thermistor Circuit Open or Shorted Backup Operating System (BOS), Checking Thermistor Resistance in Ice Bath, Dr CodeDoor Sensed Ajar or Open for more than 2 Minutes, Fresh Food Compartment Door Adjustment Criteria, L1 Op CodeOpen High Temperature Limit Switch, No AC CodeAc Mode Selected/ AC Voltage Not Available, No FL CodeBurner Failed to Light/Relight, Electrical Power Requirements and Components, Light/Thermistor Wire Assembly Replacement, Flapper Assembly, Left Door, Fresh Food Compartment, Removable Door Seal Heater Spring Pin Removal and Installation, Harness Connector Optical Control Display Circuit Board, Diagnostic Screen 5, Segment 7, no Cooling Sensed, Location of Original High Temperature Limit Switch, The Present Configuration of the High Temperature Limit Switch, Cooling Unit Component Location -Lower Section, Sealant Application on Cabinet Opening Sides, Checking for Gas Leaks after Installation, Water Adjustment Screw and Contact Alignment Location, Checking Water Valve Solenoid Coil Resistance, Measuring Solenoid Coil Resistance through Wire Harness, Checking Voltage to the Stepper Motor Connection, Refrigerator Norcold 121X Series Service Manual, Refrigerator Norcold 1210 Installation Manual, Refrigerator Norcold 121X series Owner's Manual, Refrigerator Norcold 1200XX Owner's Manual, Refrigerator Norcold 121XAC series Installation Manual, Refrigerator Norcold 1210ACIM Owner's Manual, Refrigerator Norcold 121X AC Series Owner's Manual, Refrigerator Norcold 121 AC series Installation Manual, Refrigerator Norcold 120X Series Owner's Manual, Refrigerator Norcold 120X Installation Manual, Refrigerator Norcold 1200LR Service Manual & Parts List, Refrigerator Norcold 1200 Installation Manual, Refrigerator Norcold 1200 Series Service Manual, Page 68: Cooling System Diagnostic Flowchart. Just make sure you push it far enough back its out of the way. To solve this problem people add insulation on the back wall to help close the gap. But even the best appliances need a little bit of care and maintenance from time to time.